ATC, ATP, ATF Clamp-On Thermostat

Brand: Danfoss

ATC CLAMP-ON CYLINDER THERMOSTAT: The ATC clamp-on cylinder thermostat, which comes complete with cylinder fixing strap, is confi gured specifi cally for the control of domestic hot water cylinders. 

The thermostat, which utilizes a bi-metallic strip provides reliable and repeatable control, over a wide range of temperatures [30° to 90° C (86° to 194° F)]. The electrical contacts provide single pole double throw operation making the thermostat suitable for all types of motorised valves, including 3 port mid-position types. The thermostat, which is not pre-wired, incorporates a sturdy mechanical cable gland which enhances installation standards. 

ATP CLAMP-ON PIPE THERMOSTAT: The ATP clamp-on pipe thermostat, which comes with a pipe fi xing strap, is confi gured specifi cally for use as a pipe thermostat, and is suitable for use on pipes of up to 2" diameter (50 mm). The thermostat utilizes a bi-metallic strip. The metal base of the thermostat makes direct contact with the pipe. This type of construction provides accurate and repeatable control. 

Typical applications include:
  • Pump run on thermostat.
  • Safety thermostat for use in solid fuel heating systems.
  • Shunt pump control in oil fired installation.
ATF CLAMP-ON FROST PROTECTION THERMOSTAT: The ATF clamp-on pipe thermostat has a set range of [10° to 90° C (50° to 194° F)]. The lower set point of 0° C (32° F) makes the thermostat particularly suited for frost protection applications. The ATF which utilises a vapour fi lled bellows, comes with pipe fixing strap. 

The ATF can be used in most frost protection applications which require a pipe thermostat including:
  • 2nd stage operation in 2 stage frost protection schemes
  • Frost protection termination function in systems which utilise a room thermostat to initiate boiler operation during periods of low internal room temperature

Specifications

Brand

Applications

  • Pump Run on Thermostat - for ATP
  • Safety Thermostat for use in Solid Fuel Heating Systems - for ATP
  • Shunt Pump Control in Oil Fired Installation - for ATP
  • Used in Domestic Hot Water Cylinders - for ATC
  • Used in Frost Protection Application - for ATF

Electrical Rating

  • 6(2) A at 220/240 Vac - for ATP Pipe Thermostat & ATF Pipe Frost Thermostat
  • 6(2.5) A at 220/240 Vac - for ATC Cylinder Thermostat

Pipe Size

  • 1/2 to 2" - for ATP & ATF Thermostat

Supply Voltage

  • 220/240 Vac, 50 Hz

Switch Type

  • SPDT

Temperature Range

  • 10° to 90° C (50° to 194° F)
show more